In the section below, you can find the most frequently asked questions (and answers) we received.

These are categorized in Operation, Reliability, Compliance, and Others.

You can select the FAQs by category or use the search function at the top of the website to directly search for information.
If you cannot find the information you are looking for, use the “DON’T FIND ANSWERS? CONTACT US” button on the top right side of our website.

3 in 1 dimming circuit would drain 0.1mA per model. Dividing the rated current of the dimmer by the 0.1mA, and we could know how many units can be controlled by one dimming device. For resistance dimming applications, resistance for 100% dimming output would be 100K ohm divided number of models.

Categories: LED Lighting, Others

3 in 1 dimming is the most common application used in LED dimming with the feature that it does not have to work with any specific dimmer. The only thing that has to be verified is that whether the dimmer (1~10V/10V PWM/resistance) is compatible with the definition advised in our specs.

Categories: LED Lighting, Others