In the section below, you can find the most frequently asked questions (and answers) we received.

These are categorized in Operation, Reliability, Compliance, and Others.

You can select the FAQs by category or use the search function at the top of the website to directly search for information.
If you cannot find the information you are looking for, use the “DON’T FIND ANSWERS? CONTACT US” button on the top right side of our website.

Some power supplies provide a “Power Good” signal when they are turned on and send out a ” Power Fail” signal when they are turned off. This is usually used for monitoring and controlling purposes.

  • Power Good: after the output of a power supply reaches 90% rated voltage, a TTL signal (about 5V) will be sent out within the next 10-500ms.
  • Power Fail: before the output of a power supply is less than 90% rated voltage, the power-good signal will be turned off at least 1ms in advance.
Categories: Industrial, Medical, Operation

1. To increase the reliability of the power supply, we suggest users choose a unit that has a rating of 30% more power than actual need. For example, if the system needs a 100W source, we suggest that users choose a power supply with 130W of output power or more. By doing this, you can effectively boost the reliability of the power supply in your system.

2. We also need to consider about ambient temperature of the power supply and whether there is additional device for dissipating the heat. If the power supply is working in a high temperature environment, we need to make some derating to the output power. The derating curve of “ambient temperature” versus “output power” can be found on our specifications.

3. Choosing functions based on your application:

  • Protection function: Over Voltage Protection (OVP), Over Temperature Protection (OVP), Overload Protection (OLP), and etc.
  • Application function: Signaling Function (Power Good, Power Fail), Remote Control, Remote Sensing, and etc.
  • Special function: Power Factor Correction (PFC), Uninterruptible Power Supply (UPS) function.

4. Make sure that the model qualifies for the safety standards and EMC regulations you need.

Categories: Industrial, Medical, Others