Do I need to derate my power supply when I used it over 2000m?

Yes, for power supplies certified >2000m please read the “note” in the spec.

In general, for unpotted models, a derating of 5°C/1000m has to be applied and for potted models, a derating of  3.5°C/1000m has to be applied.

For example LRS-75-24:

The datasheet shows:

The Note. 7 shows:

At 5000m the derating curve will need to move 15°C following the arrow (1)

At full load the maximum operating temperature at 5000m will be 35°C shown at (2)

Categories: Charging, Industrial, Medical, Operation
Tags: 5000m, altitude, derate, derating, Derating Curve, operating altitude

Contact us

Give us a call or fill in the form below and we'll contact you. We endeavor to answer all inquiries within 24 hours on business days.

For our sponsorship program for young talent, submit your proposal here.