Do I need to derate my power supply when I used it over 2000m?

Yes, for power supplies certified >2000m please read the “note” in the spec.

In general, for unpotted models, a derating of 5°C/1000m has to be applied and for potted models, a derating of  3.5°C/1000m has to be applied.

For example LRS-75-24:

The datasheet shows:

The Note. 7 shows:

At 5000m the derating curve will need to move 15°C following the arrow (1)

At full load the maximum operating temperature at 5000m will be 35°C shown at (2)

Categories: Charging, Industrial, Medical, Operation
Tags: 5000m, derate, derating, Derating Curve

Contact us